Internal Wall Insulation - Design – Schneider Woodfibre Boards & Thermafleece Sheeps Wool
Bethany Evans Posted this on 29 May 2024
500mm Solid Wall (appropriate external protection from driving rain is essential when undertaking internal wall insulation – please contact us for advice) |
Approx 15mm hydraulic lime plaster |
Option 4 (Sheep's wool & woodfibre) |
100mm of insulation chosen from below |
Tŷ-Mawr Thermafleece Cosywool/Ultrawool/NatraHemp |
Moisture variable vapour check |
Woodfibre board T&G 40mm fixed with plastic washers and screws at 8 per m2 |
2 x 6mm Fine Hemp Plaster with mesh* which can be finished with 1 x 3mm Superfine Plaster for a finer finish or 1 x 10mm Base Coat SecilTek Isovit (meshed) & 1 x 3mm Top Coat SecilTek Cal AC *preferred option |
Vapour permeable Paint Finish - Maxil, Tŷ-Mawr Limewash, Clay Paint, Ecosphere |
Table shows typical thicknesses suitable for internal wall insulation, but please contact us for a specific u-value calculation, condensation risk analysis and quotation for your project. |