External Wall Insulation - Design – Schneider Woodfibre Boards
Bethany Evans Posted this on 07 Jun 2024
500mm – 600mm Solid Wall |
Option 1 (Woodfibre) For different thicknesses/insulation values please contact our technical advisors. |
Approx 15mm levelling coat of Hydraulic Lime Plaster* |
Adhesive 10mm combed coat |
Woodfibre boards 120mm fixed with insulated fixings at a typical fixing rate of 8 per m2 |
Board manufacturers proprietary render system following manufacturer’s instructions 1 x 10mm Base Coat SecilTek Isovit (meshed) & 1 x 3mm Top Coat SecilTek Cal AC |
Vapour permeable paint finish - Silicate masonry paint, Tŷ-Mawr limewash |
*as specified by Tŷ-Mawr Ltd. Please note different insulation thicknesses are available if there is not a Building Regulations requirement |
Table shows typical thicknesses suitable for external wall insulation, but please contact us for a specific u-value calculation, condensation risk analysis and quotation for your project. |